Skip to main content

Creating a new Distribution Box

Creating a distribution box is similar to creating a cable, but it has more components and options. A distribution box can have multiple inlets and outlets, as well as more complex routing and testing requirements.

In this example we will create a distribution box with one CEE 16A inlet and three 16 A shuko outlets protected by one three phase RCD.

Adding components​

The way to add components to a distribution box is the same as for a cable, but you have more options to choose from. First add all required sockets, then switch to the RCD tab to add all required RCDs.
To speed up the process, you can add multiple outlets at once by selecting them in the list. The same applies for RCDs.

add outlets

add rcd

Routing​

After adding all components, you can start routing the box. The easiest way is to drag & drop from the components to the routing side, but you can also use the route group editor to change the routing of individual sockets.

Start by clicking on the RCD, or the inlet if you want to route without RCD.
Then click on Add Sockets, select all sockets you want in this RCD.
In this example, the three phase RCD requires socket 2 and 3 to use Phase L2 and L3 as well, so we will directly change the routing.

routing

When all is done, all components show green and the box is ready for testing.

note

Though technically PhasePE is not routed through an RCD, it has no effect on the tests if it is defines as routed through the RCD.
Disabling the Use tickbox is an advanced feature that can be used to define sockets that use multiple circuit. See multipole boxes for more information.

Finished!​

Your box is ready for testplans and serial numbers.

finished box