Skip to main content

Multipoles with multiple circuits

You can define distribution boxes with rare multipole sockets carrying more than one circuit.
Within these connectors there are multiple circuits of Phase/Neutral/Earth pins exist, each can be protected by its own RCD.

See the example below:

3x3 rectangular plug with three L/N/PE groupsSimple rectangular plug diagram with three columns of pins, each column containing L, N and PE, colored brown, blue and yellow, grouped with dotted outlines labelled group 1, 2 and 3Group 1L1NPEGroup 2L2NPEGroup 3L3NPE
note

Examples of these sockets include Harting or Socapex connectors.
Use of multiple protected circuits within a single connector may be subject to specific local electrical regulations.

How to route multipole sockets​

Routing multipole sockets requires special attention with the routing.

  1. Create a Test Object as normal, provide the name and other necessary details.
  2. Add the relevant components required, sockets, rcd.
  3. Simple sockets that can be routed using the normal drag & drop method.

Then, multipole sockets that require grouped routing require special handling to ensure that all circuits are correctly connected and protected.

  1. Click on the RCD you want to route a circuit group to.
  2. Select the socket you want to connect pins from.
  3. Select the pins you want to connect to this earlier RCD.

See below example, two groups of circuit are already routed.

Select pins for a circuit group

If you have a common PE pin you can route this to the Inlet socket using the same method as shown above.

note

It is currently not possible to store custom pin layouts for multipole sockets as defintions permanently.
Contact us to have your layout added as a standard definition.

Pin Classes​

If your multipole sockets uses a custom pin layout you must change the definition of the socket used in this Test Object.
You can edit inlet and outlet socket pins in the same way.

tip

It works best if this is performed before you start routing.

  1. Click on the socket in the hardware area on the left to open the editor.
  2. Toggle the switch above the pin column to enable custom pin configuration.
  3. Change the pin class assignments as required for your multipole socket.

redefine-pins.gif

Limitations​

Some limitations apply to this function.

Inlet Socket Limitation​

Currently you can only define a single inlet socket.
Combiner boxes that adapt multiple circuits into a single multipole socket are not supported at this time.

Within-socket connections​

If your test object has jumpers, or within-socket connections, these cannot be defined.