Chassis clamp
The earth or chassis clamp is used to test frames or exposed metal parts. It verifies either:
- chassis earthing with sufficiently low resistance
- chassis insulation for double-insulated test objects in a metal frame for example
- earthing bolts or screws
High voltage may be present on exposed parts of the clamp and test object during testing. Defects may also cause high voltage on the test object chassis.
Always follow all safety precautions.
Always put the chassis clamp back on the plastic holder when finished testing.
Do not clamp onto the frame or other conductor parts when not in use.
Special test method
When a Chassis Point is used an additional isolation test is performed using all inlet pins against the chassis clamp.
This is done to verify that the frame is properly isolated from all circuits.
Correct connection of the chassis clamp is validated at the beginning of the test.
If not connected the test will not continue.
Testobject with earthed frame
To create a testobject with an earthed frame, add a Crocodile Chassis Point to the testobject.
This will add a location the chassis clamp should attach to, and route it to the PE circuit.
Testobject with isolated frame
To create a testobject with an isolated frame, add a Crocodile Chassis Point to the testobject.
This will add a location the chassis clamp should attach to, and mark the routing NC (not connected).

A Chassis Clamp socket with a NC pin does not require further routing.
Ground terminal
Grounding bolts terminals can also be tested with the Crocodile Chassis Point.
You may be asked to re-connect during the test if you have multiple chassis points defined.
Care must be taken not to damage the thread on the grounding terminal when connecting the chassis clamp.