Universal Sockets
Universal sockets are used to test rare or special plugs that are not always present on the EST by making an adapter cable for the desired plug. With custom adapters, the 4-wire measurement is extended up to the test socket, allowing for precise resistance measurements of cables and connections. Not influenced by the resistance of the adapter cable.
Custom adapters
To create a custom adapter, find the size of Universal socket on your EST and order the appropriate components.
Then wire each pair of the universal socket to the desired plug, ensuring the pair is linked inside the test socket pin terminal.
See the tables below for the pin mapping of the universal socket.
If in doubt, consult EMRI for assistance in creating a custom adapter.
Safety
Custom adapters must only be made by qualified personnel.
Each adapter must be labeled with a name, date, and serial number to enable proper documentation of periodic inspections.
- Do not create shorts or links between the pin pairs of the universal plug.
- Do not create dangerous male-to-male or female-to-female adapters.
- Do not create adapters that allow for the connection of live voltage to the EST.
- Do not create adapters that allow for the connection of external test equipment to the EST.
- Do not create adapters with exposed conductive parts, only use existing CE-compliant connectors or plugs.
The EST will validate pins in the universal plug are correctly wired each time a test is run.
If the pins are not wired correctly, the EST will not allow the test to start.
10 pole universal socket adapter
The 10 pole universal plug adapter allows for testing of plugs with up to 10 poles. It uses 20 pins on the EST side.
| EST Pin # | Test Pin # |
|---|---|
| 1 | Source Pin 1 |
| 2 | Measure Pin 1 |
| 3 | Source Pin 2 |
| 4 | Measure Pin 2 |
| ... | ... |
| 21 | Reserved, leave open |
| 22 | Reserved, leave open |
| 23 | Reserved, leave open |
| 24 | Reserved, leave open |
| Component | Qty | Part |
|---|---|---|
| Housing | 2 | HC-EVO-B24-HHFS-PLBK |
| Cable entry | 2 | HC-B-G-M25-PLRBK |
| Male insert | 1 | HC-B24-I-TPT-M |
| Female insert | 1 | HC-B24-I-TPT-F |
| Cable | 1 m | at least 20x1 eg: Jobarco 0150425 PUR sheath |
Limitations
Limitations apply to the universal plug:
- The universal plug is not able to inject test voltage for functional or RCD testing.
- Insulation test is performed on all pins, even those not used by an adapter. This may result in a longer test time.
- Per EST, only one universal socket pair can be fitted per size.