Report Definitions
Using the Report Definitions button on the homepage all available report definitions can be accessed.

Creating Custom Report Definitions
To create a custom report definition, click on the Create+ button, Choose which type of template you want to start from and select the desired template. You can then customize the report definition according to your needs.
We strongly recommend to start with an existing report template rather than creating a 'New Report' one from scratch.
Modifying Reports Templates
You can also modify the existing report definition to better suit your needs.
Click on the Edit button of the report definition you want to edit from the list of available templates and make the necessary changes.
You are allowed to modify existing default report templates. You cannot change the templates available in Create+.
Editor
An extensive user manual for the editor itself can be found at the following link:
https://docs.devexpress.com/eud/eud-for-devexpress-reports/reporting-for-web/report-designer

Saving modifications
To save a report definition, click on the hamburger menu on the left and choose Save or Save As after making the necessary changes.
Available Data Fields
The reporting engine is exposed to a hierarchical data structure representing test results, subtest results, and associated test objects.
Below you will find a description of the structure and all available fields.
Labels have a reduced subset of fields compared to the full data structure.
Data Structure
Data is structured in a hierarchical manner, with the main test result at the top level and subtest results with their specific measurements underneath.
- Each test session is represented by a
MainTestResultin the data structure. - Each serial numbered object is represented by a
TestObjectInstancein the data structure. - Each test is executed under a new
SubTestResult.- This means each type of test has it's own
SubTestResult. - This also means, if the object is re-wired due to multiple partial tests, each test after the re-wiring will have its own
SubTestResult.
- This means each type of test has it's own
- Each individual measurement is represented by a
TestResultin the data structure.
An example may look like this:
MainTestResult
├── TestObjectInstance
| └── TestResult
|
├── SubTestResult Connection Test
│ ├── TestResult Socket 1
│ └── TestResult Socket 2
├── SubTestResult Resistance Test
│ ├── TestResult
│ └── TestResult
├── ...
├── SubTestResult Connection Test (part 2)
│ ├── TestResult Socket 3
│ └── TestResult Socket 4
└── SubTestResult Resistance Test (part 2)
├── TestResult
└── TestResult
Report parameters
The following parameters are provided by the reporting engine itself.
| Parameter | Type | Purpose |
|---|---|---|
ResultId | int | ID of the test result to print |
timezoneOffset | string | Timezone offset in hours from where the report is generated |
timeZone | string | Timezone from where the report is generated |
Use the following syntax for these parameters, for example ?ResultId and ?timezoneOffset.
Main test result fields
The MainTestResult is the origin of all data in the report.
| Field | Type | Description |
|---|---|---|
SubTestResults | Collection | Individual subtest results |
TestObjectInstance | TestObjectInstance | Instance of the tested object |
AmbientTemperature | float | Ambient temperature during testing |
AppVersion | string | Application version used during the test |
Comment | string | Optional operator comment |
EstSerialNr | string | Serial number of the EST used for testing |
Id | int | Unique test-result identifier |
OperatorId | string | Database ID of the operator |
OperatorName | string | Name of the operator |
Pass | bool | Overall Boolean pass/fail value |
TestObjectDescription | string | Description of the tested object |
TestObjectInstanceId | int | ID of the tested object instance |
TestObjectName | string | Name of the tested object |
TestObjectSerialNr | string | Serial number of the tested object |
TestPlanDescription | string | Stored test-plan name, version, or description |
TestPlanId | int | ID of the test plan |
TestPlanName | string | Name of the test plan |
TestResult | Test Result Enum | Overall result classification |
TimeStamp | DateTime | Date and time when the test was executed |
ValidUntil | DateTime | Validity date and time of the result |
Test object instance fields
TestObjectInstance identifies the physical object that was tested.
| Field | Type | Description |
|---|---|---|
Id | int | Unique identifier of the object instance |
Name | string | Object-definition name; not persisted on the instance |
SerialNumber | string | Serial number of the object |
TestObjDefId | int | ID of the object definition |
TestResults | Collection | All test results belonging to this object instance (only one result is provided) |
Subtest fields
Each item in SubTestResults exposes the following fields:
| Field | Type | Description |
|---|---|---|
Discarded | bool | Whether the result was discarded, usually after a retry |
Id | int | Subtest result identifier |
MainTestResultId | int | Parent result ID |
SubTestType | SubTest Type Enum | Type of subtest |
TestCONResults | Collection | Connection measurements |
TestFUNCResults | Collection | Functional test results |
TestINSResults | Collection | Insulation measurements |
TestRCDResults | Collection | RCD measurements |
TestRESResults | Collection | Resistance measurements |
TestPlanStepNr | int | Test-plan step number |
TestResult | Test Result Enum | Result of the subtest |
TestStrategy | string | Strategy used for the subtest |
TestVISUResults | Collection | Visual inspection results |
Timestamp | DateTime | Subtest execution timestamp |
The available collection paths are:
SubTestResults
SubTestResults.TestCONResults
SubTestResults.TestINSResults
SubTestResults.TestRESResults
SubTestResults.TestRCDResults
SubTestResults.TestVISUResults
SubTestResults.TestFUNCResults
Measurement fields
All measurement result have these common fields:
| Field | Type | Description | Remarks |
|---|---|---|---|
Attempts | int | Number of attempts | |
Discarded | bool | Whether the measurement was discarded | Not used |
Id | int | Measurement-result identifier | |
PassCriteria | string | Criteria or norm used for evaluation | |
TestInstrument | string | Instrument or measuring device | |
TestResult | Test Result Enum | Measurement result | |
TestSubTestResultId | int | Parent subtest ID | |
Timestamp | DateTime | Measurement timestamp |
Connection fields
Each connection test result contains the following fields:
| Field | Type | Description |
|---|---|---|
Details | string | Failure or diagnostic details |
InLetPinCode | string | Inlet-pin code |
MeasureResult | Connection Test Result Enum | Detailed continuity result |
OutletPinCode | string | Outlet-pin code |
PinDescription | string | Tested pin description |
PinNr | int | Tested pin number |
RouteCode | string | Connection-route code |
SocketCode | string | Socket code |
SocketName | string | Tested socket name |
SocketNr | int | Tested socket number |
TestObjInletPinId | int | Tested inlet-pin definition ID |
TestObjOutletPinId | int | Tested outlet-pin definition ID |
TestObjRouteId | int | Tested route definition ID |
TestObjSocketId | int | Tested socket definition ID |
Available under SubTestResults.TestCONResults
Insulation fields
Each insulation test result contains the following fields:
| Field | Type | Description |
|---|---|---|
MeasureResult | Insulation Test Result Enum | Detailed insulation result |
MsrResultValue | decimal | Processed insulation-resistance value |
PinH | string | High-potential pin |
PinL | string | Low-potential pin |
RawValue | double | Raw, unrounded measurement value |
TestVoltage | decimal | Test voltage |
Available under SubTestResults.TestINSResults:
Resistance fields
Each resistance test result contains the following fields:
Protective Conductor results are also resistance results, they differ from normal resistance result by their SubTestResult.Strategy.
| Field | Type | Description |
|---|---|---|
MeasureResult | Test Result RES Type Enum | Detailed resistance result |
MsrResultValue | decimal | Processed resistance value |
PinDescription | string | Tested pin description |
PinNr | int | Tested pin number |
RawValue | double | Raw, unrounded measurement value |
SocketName | string | Tested socket name |
SocketNr | int | Tested socket number |
TemperatureCompensated | bool | Whether temperature compensation was applied |
TestCurrent | decimal | Test current |
TestObjRouteCode | string | Tested route code |
TestObjRouteId | int | Tested route definition ID |
Available under SubTestResults.TestRESResults:
RCD fields
Each RCD test result contains the following fields:
| Field | Type | Description |
|---|---|---|
MeasureResult | RCD Test Result Enum | Detailed RCD result |
MsrResultValue | decimal | Measured RCD value |
RcdName | string | RCD name |
RcdNr | int | RCD number |
TestCurrent | decimal | AC test current |
TestedSocket | string | Socket used to test the RCD |
TestedSocketNr | int | Number of the tested socket |
TestObjRcdId | int | Tested RCD definition ID |
TestType | RCD Test Type Enum | RCD test type |
VerifiedSockets | string | Sockets checked after RCD tripping |
Available under SubTestResults.TestRCDResults:
Visual fields
Each visual test result contains the following fields:
| Field | Type | Description |
|---|---|---|
Comment | string | Operator comment |
TimeToAnswer | TimeSpan | Time taken to answer the visual question |
Available under SubTestResults.TestVISUResults in addition to the common measurement fields:
Functional fields
Available under SubTestResults.TestFUNCResults in addition to the common measurement fields:
| Field | Type | Description |
|---|---|---|
Comment | string | Operator comment |
TimeToAnswer | TimeSpan | Time taken to answer the functional question |
Enums
Some data fields are an enumeration of possible values.
SubTest Type Enum
The type of subtest performed.
| int | Value | Description |
|---|---|---|
| 0 | Undefined | Subtest type is not specified |
| 1 | VISU | Visual Test |
| 2 | CON | Connection Test |
| 3 | RES | Resistance Test |
| 4 | INS | Insulation Test |
| 5 | RCD | RCD Test |
| 6 | FIN | Finalizing Connection Test |
| 7 | FUNC | Functional Test |
Test Result Enum
The test result of a test plan execution.
| int | Value | Description |
|---|---|---|
| 0 | Undefined | Test is not performed |
| 1 | Pass | Test passed |
| 2 | Fail | Test failed |
| 3 | Error | Test stopped on error |
| 4 | Aborted | Test aborted by user |
| 5 | Skipped | Test skipped |
Connection Test Result Enum
| int | Value | Description |
|---|---|---|
| 0 | Undefined | Test is not performed |
| 1 | Ok | Connection Ok |
| 2 | Open | No Connection Ok |
| 3 | Closed | No connected expected, but was measured closed |
| 4 | Break | Connection expected but measured open |
| 5 | Short | Connection expected but also found on different pin |
| 6 | Miswired | Connection expected but detected on different pin |
Insulation Test Result Enum
| int | Value | Description |
|---|---|---|
| 0 | Undefined | Test is not performed |
| 1 | Ok | Resistance Ok |
| 2 | Low | Measured resistance was lower then allowed |
| 3 | High | Measured resistance was higher than allowed |
| 4 | Short | Measured a short circuit or overload of high voltage bias |
RCD Test Result Enum
| int | Value | Description | Remark |
|---|---|---|---|
| 0 | Undefined | Test is not performed | |
| 1 | Ok | Rcd Ok | |
| 2 | Low | Rcd operated at a lower current than expected | Only for tests measuring current |
| 3 | High | Rcd operated at a higher current than expected | Only for tests measuring current |
| 4 | Fast | Rcd operated too fast (eg: for selective RCD) | Only for tests measuring time |
| 5 | Slow | RCD did not operate fast enough | Only applicable for tests measuring time |
| 6 | NoTrip | RCD did not operate at all | |
| 7 | PartialTrip | RCD did operate, but not all downstream sockets were isolated |
RCD Test Type Enum
The type of RCD test performed.
| int | Value | Description | Purpose |
|---|---|---|---|
| 0 | Undefined | Test type is not specified | |
| 1 | RCD Time | RCD Time | Test trip time (time result) |
| 2 | RCD Value | RCD Value | Test trip value (current result) |
Resistance Test Result Enum
| int | Value | Description |
|---|---|---|
| 0 | Undefined | Test is not performed |
| 1 | Ok | Resistance Ok |
| 2 | Low | Measured resistance was lower then allowed |
| 3 | Open | Connection expected but measured open |
| 4 | High | Measured resistance was higher than allowed |
| 5 | Asymmetric | The connection measured outside tolerable mean of the socket |
Label template fields
A label uses a reduced subset of all results and only exposes the following fields:
| Field | Type | Description |
|---|---|---|
AmbientTemperature | float | Ambient temperature during the test |
AppVersion | string | Application version |
Comment | string | Operator comment |
EstSerialNr | string | Estimated serial number |
Id | int | Test result ID |
OperatorId | string | Operator ID |
OperatorName | string | Operator name |
Pass | bool | Whether the test passed |
TestObjectDescription | string | Test object description |
TestObjectInstanceId | int | Test object instance ID |
TestObjectName | string | Test object name |
TestObjectSerialNr | string | Test object serial number |
TestPlanDescription | string | Test plan description |
TestPlanId | string | Test plan ID |
TestPlanName | string | Test plan name |
TestResult | Test Result Enum | Overall test result |
TimeStamp | DateTime | Timestamp of the test |
ValidUntil | DateTime | Validity of the test result |