Creating a new Cable

In this example we will create a straight CEE 63A 400V 5-pole cable. A cable is the simplest type of test object, it only has an inlet and an outlet. First navigate to the Test Object page and click the "New" button.
This will open a form where you can enter the details of the cable, such as its name, type, and description. Then, enter a Name, select "Cable" as the type, optionally provide a description.

Cable Cable

Name will be used to identify the test object in the EST later, so it should be unique and descriptive.
Type can be either "Cable" or "Distribution Box". This will determine the components and type of tests that can be performed on the test object.
Description is optional, but it can be useful to provide additional information about the test object, such as its components or variant information.

tip

You can use part numbers in the name field, this can be helpful for automation. In such case the description should receive extra attention.

note

Do not use serial numbers in the name field.
A test object is a definition of a distribution box or cable from which many instances can exist and that is related to the test properties setup that describes how to test.
It is not an actual unique traceable object, but rather a template that is used for testing.

Adding components​

After creating a test object, you can add components to it. Components are the individual parts of the test object that can be tested, such as outlets, inlets, connectors and plugs. To add a component, click the "Add" button near the "All Hardware" section (left).

add component

This will open a list of available Sockets to add, followed by a list to select the outlet.
Filters or search can be used to quickly find the component you want to add.

add socket list

Cable properties​

For cables it is important to set the correct conductor size and length, as this will be used to determine the limits for the tests.
To set the properties of a cable, click on the socket in the "All Hardware" box.

The edit socket dialog shows all pins, possible incompatible EST and routing information.

conductor properties

Connection Class​

The connection class defines the fundamental class of the pin, such as L1, L2, L3, N or PE. This is used to determine routing and choose the best suitable measurements. To modify connection classes in sockets, you must first tick the checkbox in the table header, this will enable editing.

Only change connection classes when you are creating an exception, for example when you have sockets with a not-connected (NC) pin.

ClassDescription
PhaseL1/L2/L3Typical three phase power
Phase_NNeutral
PhasePEProtective Earth
DataData (low voltage)
OtherOther (eg: dc power)
NCNot Connected

Test Object Compatibility​

When adding components, a continuous check will verify if these sockets are available for testing on the ESTs in your company.

compatibility

Routing the socket​

For straight cables the easiest way is to drag & drop from the components to the routing side.
When all sockets are routed, all components show green.

drag and drop

Changing the routing​

It is possible to change the routing of the cable, for example to change the phase sequence.
Click any socket in the routing section to open the route group editor. From this dialog you can change to which Inlet pin the Outlet is connected.

route group editor

Saving the test object​

After creating the test object, click the "Save" button to save it.
If you have made changes to an existing test object, the software asks if this is a new test object or if you want to correct the existing one.

To maintain consistency of the test results and related serial numbers, you cannot change test objects.

save test object

If you Correct a test object:

  • a new version is created
  • the testplans are migrated
  • the serial numbers are migrated
  • all previous test results remain linked to the old version

If you Save as new a brand new test object is created. Optionally you can choose to copy the test plans. For cables this is not recommended, see below.

info

The limit values for cables are only calculated upon test plan generation. If you use Save as New with duplication of test plans, the limits will be copied as well.
This can lead to incorrect limits if you change the conductor size or length of the cable. In such case it is better to keep Duplicate off and create new test plans, this will ensure the limits are calculated correctly.

Finished!​

After saving the test object, it is ready to be used in test plans and for testing on the EST.